Instruments of Trace analysis (B02)

ICP-MS Mass spectrometer
GC-MS1 GC-MS2
GC-MS3 WDXRF
μXRF Raman
FT-IR Elemental analyzer
HPLC Ion chromatograph
High resolution mass spectrometer Printer

ICP-MS (Inductivity Coupled Plasma Mass Spectrometer)

ICP-MS
Model Agilent 8800
Mass analysis "Triple-Quadrupole" tandem MS configuration
Detection limit ppt
Form of sample Liquid
Mode Qualitative, Quantitative, MS/MS
Accessory devices Autosampler
Applications By making the sample as a solution, various quantitative analyzes of multi-element micro quantities are possible; metal samples (iron and steel etc.), environmental samples (river water etc.), chemical samples (reagents, catalyst etc.).
Person in charge Nakano, Takahashi
Notes When using for the first time, please inform the person in charge in advance by email. There are some cautions in the preparation of samples, please contact the person in charge.

Mass spectrometer (Double-focusing magnetic sector type)

mass spectrometer
Model JEOL JMS-700
Ionization EI (Electrom ionization)
FAB (Fast atom bombardment)
Accelerating voltage 1 - 10 kV
Mass range - 24,000 Da at 1kV
Resolution over 60,000
Applications Accurate mass measurement
Person in charge Mochizuki
Notes Please contact the person in charge before using.
In accurate mass measurement, please show the molecular formula of the sample and the calculated exact mass (in the case of FAB, the mass protonated ion is also required).
For the measurement sample, prepare about 1mL of a solution of about 0.01mol/L for EI. For FAB, please prepare about 100 mg without dissolving the sample. We use Glycerin, m-nitrobenzyl alcohol (NBA), polyethylene glycol (PEG) as a typical FAB matrix.

GC-MS1 (Gas chromatograph mass spectrometer1)

GC-MS
Model Agilent 6890N (GC), 5975C (MS)
Ionization EI (Electron ionization)
Mass range 1.6 - 1,050 Da
Columns DB-1ms, HP-5ms, DB-1701, HP-PLOT Q, CP-PoraBOND Q ,etc
The user's column is also available.
Accessory devices Autosampler (for liquid)
Applications Quantitative or qualitative analysis of volatile materials
Person in charge Mochizuki
Notes Please contact the person in charge before using.
Remove nonvolatile salts and suspensions from the liquid sample. For quantitative analysis, prepare a standard sample for calibration curve.
Gas sample is available.Quantitative analysis of gas samples is accepted only for samples collected in a gas collection bag with a cock.
This device is mainly used for analyzing gas samples.

GC-MS2 (Gas chromatograph mass spectrometer2)

GC-MS2
Model Agilent 8890 (GC), 5977C (MS)
Ionization EI (Electron ionization)
Mass range 0.6 - 1,091 Da
Columns DB-1ms, HP-5ms, DB-1701,etc
The user's column is also available.
Accessory devices Autosampler (for liquid)
Applications Quantitative or qualitative analysis of volatile materials
Person in charge Mochizuki
Notes Please contact the person in charge before using.
Remove nonvolatile salts and suspensions from the liquid sample. For quantitative analysis, prepare a standard sample for calibration curve.
Quantitative analysis of gas samples is accepted only for samples collected in a gas collection bag with a cock.

GC-MS3 (Gas chromatograph mass spectrometer3)

GC-MS3
Model Agilent 8860 (GC), 5977B (MS)
Ionization EI (Electron ionization)
Mass range 1.6~1,050 Da
Columns HP-INNOWax, DB-FFAP,etc
The user's column is also available.
Accessory devices Autosampler (for liquid)
Applications Quantitative or qualitative analysis of volatile materials
Person in charge Mochizuki
Notes Please contact the person in charge before using.
Remove nonvolatile salts and suspensions from the liquid sample. For quantitative analysis, prepare a standard sample for calibration curve.
Quantitative analysis of gas samples is accepted only for samples collected in a gas collection bag with a cock.

WDXRF (Wavelength Dispersive X-ray Fluorescence spectrometer)

XRF
Model Bruker AXS S8 Tiger (1kW)
Detector Gas flow detector, scintillation counter
Analyzer crystal XS-55, PET, LiF200
Detectable element Solid: C-U, Liquid/powder: Na-U
X-ray irradiation diameter ⌀5 mm, 8 mm, 18 mm, 34 mm
Form of sample Solid, powder, liquid (acids or volatile liquids are available.)
Sample size Within ⌀50 mm
Atomosphere Vacuum, He
Applications Qualitative and quantitative analysis of specific elements in solid, powder and liquid.
Person in charge Takashina
Notes Additional charge is required when performing pressure molding and pulverizing work using analysis room reagents and equipment as preprocessing.
Please contact the person in charge in advance when using for the first time.

μXRF (micro X-ray Fluorescence spectrometer)

XRF  
Model Bruker M4 TORNADO+ S26
Detector XFlash®SSD×2
X-ray source Rh
Detectable element C~Am
X-ray irradiation diameter φ20um、φ150um
Form of sample Solid, powder, liquid
Mapping Range 190mm×160mm
Stage Size 330mm×170mm、Maximum weight load 7kg
Atomosphere Vacuum, Air
Applications Qualitative and quantitative analysis of elements in solids, powders and liquids, mapping analysis, thin film analysis
Person in charge Takashina
Notes If consumables are used during measurement, an additional fee will be charged. For the time being, we will only be accepting requests for analysis.

Raman (Raman microscope)

RAMAN
Model JASCO NRS-5100
Laser wavelength 532nm, 785nm
Objective lens 5x, 20x, 100x
Long working distance (20x, 50x, 100x)
Resolution 1cm-1
Spot size 1µm at 100x
Functions Mapping, Rapid imaging, carbon analysis, surface Scan Imaging, stress analysis
Applications Molecular structure analysis of micro regions.
Person in charge takashina
Notes When using for the first time, please inform the person in charge in advance by email etc.
Please pay attention so that the objective lens does not come in contact with the sample.
It is possible to measure samples up to a maximum height of about 80 mm.
Information on the measurement position can be shared with the infrared microscope (micro-IR).

FT-IR (Fourier Transform Infrared microscope)

FT-IR
Model JASCO FT/IR-6300
Mcroscope: JASCO IRT-7000
Detector DLATGS
Mcroscope: Mid-band MCT,linear array MCT (for rapid IR imaging),InGaAs(for near IR)
Wavenumber 7800 - 350cm-1
Mcroscope: 12000 - 650cm-1
Resolution 0.07 - 16cm-1
pixel resolution: 6.25µm2, 12.5µm2
Condenser mirror 10x, 16x, 32x
Sample Solid, liquid, gas
Microscope: solid, liquid
Measurement Method Transmittance, ATR
Microscope: Transmittance, Reflectance, ATR
Applications Qualitative (quantitative) of chemical , micro site measurements, mapping analysis, infrared polarimetry, visible polarimetry etc.
Person in charge Takashina
Notes A separately charged fee is required when preparing tablets, plate making etc using the reagents of the analysis room as preprocessing.
If you are using for the first time, please contact the person in charge in advance.
Information on the measurement position can be shared with the micro laser Raman spectrometer (Raman).

Elemental Analyzer (CHNOS)

Elemental analyzer
Model Elementar, vario EL cube
Detectable element C, H, N, S, O
Combustion temperature 1150°C
Measurement technique TCD detector (C, H, N, S), IR detector (O)
Sample Solid, liquid
Amount of sample - 50mg (organic compound: 50mg, soil: 1g)
Applications Measurement of contents of carbon (C), hydrogen (H), nitrogen (N), sulfur (S), oxygen (O) such as organic matter, soil sample, coal, etc.
Person in charge Nakano, Takahashi
Notes Since it is necessary to check the state of the sample, please consult us when bringing in the sample.

HPLC (High Performance Liquid Chromatograph)

HPLC
Model Agilent 1290 InfinityⅡ LC system
Pump Flexible Pump
Settable column flow range: 0.001 - 2 mL/min(Pump pressure resistance130MPa↑),2.001 - 5ml/min(Pump pressure resistance80MPa↑)
Detector Diode array detector (190 - 950nm),Fluorescence detector,Refractive index detector
Columns Reversed-phase columns、etc
Eluents Water, acetonitrile, methanol,formic acid
Accessory devices Autosampler,Fraction collector
Applications Quantitative analysis of organic materials in solution.
Person in charge Takahashi
Notes When using it, please inform the person in charge in advance by e-mail etc. Please make sure that the sample does not contain suspensions or high concentration salt.

IC (Ion chromatograph)

IC
Model Metrohm Basic IC plus 883
Sample roop 20µL (Changeable)
Column oven r.t. - 60°C
Detector Electric conductivity
Detection method Suppressor method
Eluent Na2CO3/NaHCO3, etc.
Accessory devices Autosampler (max. 30 samples)
Applications Quantitative analysis of anions in solution.
Person in charge Takahashi
Notes When using it, please inform the person in charge in advance by e-mail etc. Please make sure that the sample does not contain suspensions or high concentration salt.

High resolution mass spectrometer(HR-MS)

HRMS
Model AB Sciex TripleTOF 5600+
Ionization method ESI (Electrosprai ionization)
APCI (Atmospheric pressure chemical ionization)
Accelerating voltage 15 kV
Mass range 50 - 40,000 Da
Mass resolution 25,000 FWHM (m/z 100)
Applications Accurate mass spectrometry, LC-MS
Person in charge Takahashi
Notes Please contact the person in charge by e-mail before using.
For accurate mass measurement, be sure to provide the molecular formula and calculated exact mass of the sample.
This device can also be used as a liquid chromatograph mass spectrometer by connecting to the HPLC in this room.

Printer

printer
Model Epson PX-H9000
Resolution 2880dpi × 1440dpi (max.)
Paper Semi-glossy photo paper
Printable size A0 (Semi-glossy photo paper)
Printing time About 20 minutes (A0, 1 paper)
Person in charge Mochizuki
Notes If you wish to use the service, please contact the person in charge by email in advance. The printing software used is PowerPoint (Windows version). Please prepare printable files as PowerPoint and PDF files. The season for graduation thesis presentations and academic conferences is very busy, so please take into consideration the printing time per page and make your request with plenty of time.